  Series 5 Series 4 Series 3
Accuracy (FS ±1 digit): ±0.1% ±0.2% ±0.3%
Sampling rate: 7,000 Hz 3,000 Hz 2,000 Hz
Resolution: 1/5,000 1/2,000 1/1,000
Data outputs: USB, RS-232, Mitutoyo, Analog USB, RS-232, Mitutoyo, Analog USB
Programmable auto output via USB/RS-232: Yes No No
MESURTM Lite software included: Yes Yes Yes
Data output functionality: By pressing DATA button, or requesting from a PC or other device By pressing DATA button, or requesting from a PC or other device (currently displayed reading only) By pressing DATA button, send current reading only. Cannot request externally.
ASCII command set for external control (Gauge Control Language 2): Full command set "?" only
(request current reading)
None
Communication with MESURTMgauge and MESURTM Lite: Full communication Send data from gauge or request from software (single readings or continuous readings) Send current (single) readings only, cannot request from software
Communication with ESM301 test stand and Series DC controllers: Full communication, including PC control Stop/reverse at force set points, overload protection, and communication through the “?” character only None
Data memory: 1,000 readings with output, with individual data point deletion, or clear all 50 readings with output, with individual data point deletion, or clear all. No
Statistics calculations and output to PC: Yes Yes N/A
Averaging mode: Yes No No
External trigger mode: Yes No No
Analog load bar graph shown on display: Yes Yes Yes
On-screen set point (pass/fail) indicators: Yes, with markers on analog load bar graph Yes, with markers on analog load bar graph Yes, with markers on analog load bar graph
Display: Graphic, backlit LCD, with backlight auto-off Graphic, backlit LCD, with backlight auto-off Graphic, backlit LCD, with backlight auto-off
Password protection: Yes, for calibration and individual keys No No
Peak readings always displayed: Yes Yes Yes
Set points: High / low indicators, with output (dedicated pins for high and low) High / low indicators, with output (dedicated pins for high and low) High / low indicators,
no output
Programmable audible tones (beeps): Yes Yes Yes
Certificate of calibration: NIST-traceable with data (10 points in each direction) NIST-traceable with data (10 points in each direction) NIST-traceable without data (data is available for an additional charge)
Configurable calibration (weight increments and no. of data points): Yes Yes Yes
Overload outputs: Dedicated pins for tension and compression Dedicated pins for tension and compression No
No. of units of measurement: 5 5 3
Capacity range /
no. of capacities:
0.12 lbF – 1000 lbF
[0.5 N - 5000 N] / 12
0.12 lbF – 500 lbF
[0.5 N - 2500 N] / 11
0.12 lbF – 500 lbF
[0.5 N - 2500 N] / 11
Reversible housing: Yes Yes Yes
Dimensions: 2.5 x 5.9 x 1.3 in.
[64 x 150 x 33 mm]
2.5 x 5.9 x 1.3 in.
[64 x 150 x 33 mm]
2.5 x 3.9 x 1.5 in.
[64 x 99 x 38 mm]

  Series 5 Series 4 Series 3
Accuracy (FS ±1 digit): ±0.1% ±0.2% ±0.3%
Sampling rate: 7,000 Hz 3,000 Hz 2,000 Hz
Resolution: 1/5,000 1/2,000 1/1,000
Data outputs: USB, RS-232, Mitutoyo, Analog USB, RS-232, Mitutoyo, Analog USB
Programmable auto output via USB/RS-232: Yes No No
MESURTM Lite software included: Yes Yes Yes
Data output functionality: By pressing DATA button, or requesting from a PC or other device By pressing DATA button, or requesting from a PC or other device (currently displayed reading only) By pressing DATA button, send current reading only. Cannot request externally.
ASCII command set for external control (Gauge Control Language 2): Full command set "?" only
(request current reading)
None
Communication with MESURTMgauge and MESURTM Lite: Full communication Send data from gauge or request from software (single readings or continuous readings) Send current (single) readings only, cannot request from software
Communication with ESM301 test stand and Series DC controllers: Full communication, including PC control Stop/reverse at force set points, overload protection, and communication through the “?” character only None
Data memory: 1,000 readings with output, with individual data point deletion, or clear all 50 readings with output, with individual data point deletion, or clear all. No
Statistics calculations and output to PC: Yes Yes N/A
Averaging mode: Yes No No
External trigger mode: Yes No No
Analog load bar graph shown on display: Yes Yes Yes
On-screen set point (pass/fail) indicators: Yes, with markers on analog load bar graph Yes, with markers on analog load bar graph Yes, with markers on analog load bar graph
Display: Graphic, backlit LCD, with backlight auto-off Graphic, backlit LCD, with backlight auto-off Graphic, backlit LCD, with backlight auto-off
Password protection: Yes, for calibration and individual keys No No
Peak readings always displayed: Yes Yes Yes
Set points: High / low indicators, with output (dedicated pins for high and low) High / low indicators, with output (dedicated pins for high and low) High / low indicators,
no output
Programmable audible tones (beeps): Yes Yes Yes
Certificate of calibration: NIST-traceable with data (10 points in each direction) NIST-traceable with data (10 points in each direction) NIST-traceable without data (data is available for an additional charge)
Configurable calibration (weight increments and no. of data points): Yes Yes Yes
Overload outputs: Dedicated pins for tension and compression Dedicated pins for tension and compression No
No. of units of measurement: 5 5 3
Capacity range /
no. of capacities:
0.12 lbF – 1000 lbF
[0.5 N - 5000 N] / 12
0.12 lbF – 500 lbF
[0.5 N - 2500 N] / 11
0.12 lbF – 500 lbF
[0.5 N - 2500 N] / 11
Reversible housing: Yes Yes Yes
Dimensions: 2.5 x 5.9 x 1.3 in.
[64 x 150 x 33 mm]
2.5 x 5.9 x 1.3 in.
[64 x 150 x 33 mm]
2.5 x 3.9 x 1.5 in.
[64 x 99 x 38 mm]
Accuracy (FS ±1 digit):
±0.1%
±0.2%
±0.3%
Sampling rate:
7,000 Hz
3,000 Hz
2,000 Hz
Resolution:
1/5,000
1/2,000
1/1,000
Data outputs:
USB, RS-232, Mitutoyo, Analog
USB, RS-232, Mitutoyo, Analog
USB
Programmable auto output via USB/RS-232:
Yes
No
No
MESURTM Lite software included:
Yes
Yes
Yes
Data output functionality:
By pressing DATA button, or requesting from a PC or other device
By pressing DATA button, or requesting from a PC or other device (currently displayed reading only)
By pressing DATA button, send current reading only. Cannot request externally.
ASCII command set for external control (Gauge Control Language 2):
Full command set
"?" only
(request current reading)
None
Communication with MESURTMgauge and MESURTM Lite:
Full communication
Send data from gauge or request from software (single readings or continuous readings)
Send current (single) readings only, cannot request from software
Communication with ESM301 test stand and Series DC controllers:
Full communication, including PC control
Stop/reverse at force set points, overload protection, and communication through the “?” character only
None
Data memory:
1,000 readings with output, with individual data point deletion, or clear all
50 readings with output, with individual data point deletion, or clear all.
No
Statistics calculations and output to PC:
Yes
Yes
N/A
Averaging mode:
Yes
No
No
External trigger mode:
Yes
No
No
Analog load bar graph shown on display:
Yes
Yes
Yes
On-screen set point (pass/fail) indicators:
Yes, with markers on analog load bar graph
Yes, with markers on analog load bar graph
Yes, with markers on analog load bar graph
Display:
Graphic, backlit LCD, with backlight auto-off
Graphic, backlit LCD, with backlight auto-off
Graphic, backlit LCD, with backlight auto-off
Password protection:
Yes, for calibration and individual keys
No
No
Peak readings always displayed:
Yes
Yes
Yes
Set points:
High / low indicators, with output (dedicated pins for high and low)
High / low indicators, with output (dedicated pins for high and low)
High / low indicators,
no output
Programmable audible tones (beeps):
Yes
Yes
Yes
Certificate of calibration:
NIST-traceable with data (10 points in each direction)
NIST-traceable with data (10 points in each direction)
NIST-traceable without data (data is available for an additional charge)
Configurable calibration (weight increments and no. of data points):
Yes
Yes
Yes
Overload outputs:
Dedicated pins for tension and compression
Dedicated pins for tension and compression
No
No. of units of measurement:
5
5
3
Capacity range /
no. of capacities:
0.12 lbF – 1000 lbF
[0.5 N - 5000 N] / 12
0.12 lbF – 500 lbF
[0.5 N - 2500 N] / 11
0.12 lbF – 500 lbF
[0.5 N - 2500 N] / 11
Reversible housing:
Yes
Yes
Yes
Dimensions:
2.5 x 5.9 x 1.3 in.
[64 x 150 x 33 mm]
2.5 x 5.9 x 1.3 in.
[64 x 150 x 33 mm]
2.5 x 3.9 x 1.5 in.
[64 x 99 x 38 mm]
美國MARK新款Series 系列測力計參數對比
主站蜘蛛池模板: 黄色av免费在线 | 欧美在线视频全部完 | 无码亚洲成A∧人片在线播放 | 久久天堂综合亚洲伊人hd妓女 | 夜夜躁狠狠躁日日躁202 | 亚洲一二区视频 | jizz大全日本护士喷奶水 | 欧美一级片观看 | 五月婷婷综合国产成人一区二区三区 | 欧美日本在线播放 | 黑人粗大猛烈进出高潮视频 | 国产成人黄色在线视频 | 99久久国产综合精品SWAG | 99综合久久 | 被黑人的巨茎日出白浆 | 中文字幕AV无码不卡免费 | 国产伦理在线观看 | 免费无码A片一区二区三区天美 | 日韩激情无卡视频在线观看 | 被公牛日到了高潮 | 色欲A∨无码蜜臀AV免费播 | 国产成人在线播放免费视频 | 一边吃奶一边做爰爽到爆视频 | 91美女吸乳羞羞网站 | 亚洲永久在线观看 | 国产特黄在线 | 18禁无码无遮挡在线播放 | 粉嫩av一区二区老牛影视 | 亚洲iv一区二区三区 | 宝贝张开腿嗯啊高潮了视频 | 久久午夜精品影院一区 | 欧美综合影视自拍 | 麻豆入口国产精品 | 筋肉雄汁gay雄汁外送网站 | 国产中文字幕亚洲 | 亚洲毛片无码专区亚洲乱 | 成人欧美亚洲 | 国产在线一区二区三区激情欧美 | 久久av每日更新免费观看 | 亚洲一区二区三区四区五区中文 | 天堂蜜桃一区二区三区 |